CATEGORIES
CATEGORIES
Performance Data | GCHLP 3000 |
Rated Capacity in Low Pressure (LP) | 3000 lpm @ 10 bar |
3200 lpm @ 7 bar | |
Rated Capacity in High Pressure (HP) | 300 lpm @ 40 bar |
Require Power (LP) | 100 Kw @ 3200 rpm |
85 Kw @ 3000 rpm | |
Require Power (HP) | 85 Kw @ 2960 rpm |
Suction Iniet | 140 mm |
Priming Performance Range | 0 to 7.5 meters |
Priming Speed Rance | 100 – 2500 rpm |
Thermal Relief Valve Activation | 550 C – 600 C |
Typical Dimension in mm (L x W x H) | 755 / 788 /643 mm |